Aero-Flex NAV-402AP-3 User Manual

Browse online or download User Manual for Power generators Aero-Flex NAV-402AP-3. Aero-Flex NAV-402AP-3 User's Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - NAV-402AP-3

Ramp Test SetNAV-402AP-3Operation Manual1002-0906-200Issue-3

Page 2

OPERATION MANUAL NAV-402AP-3 TABLE OF CONTENTS Page 1 Sep 1/04 TABLE OF CONTENTS Title Chapter/Section Title / Copyright Page Statements Safet

Page 3

OPERATION MANUAL NAV-402AP-3 TABLE OF CONTENTS Page 2 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 4

OPERATION MANUAL NAV-402AP-3 INTRODUCTION Page 1 Sep 1/04 INTRODUCTION - NAV-402AP-3 TEST SET This manual contains NAV-402AP-3 operating instruc

Page 5

OPERATION MANUAL NAV-402AP-3 INTRODUCTION Page 2 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 6

OPERATION MANUAL NAV-402AP-3 TABLE OF CONTENTS Page 1 Sep 1/04 CHAPTER ONE NAV-402AP-3 TEST SET OPERATION MANUAL TABLE OF CONTENTS Title Chapte

Page 7

OPERATION MANUAL NAV-402AP-3 TABLE OF CONTENTS Page 2 Sep 1/04 Title Chapter/Section/Subject Page SECTION 3 – SPECIFICATIONS 1-3 1. NAV-402A

Page 8

OPERATION MANUAL NAV-402AP-3 LIST OF ILLUSTRATIONS/TABLES Page 1 Sep 1/04 LIST OF ILLUSTRATIONS Title Chapter/Section/Subject Page Battery Rec

Page 9

OPERATION MANUAL NAV-402AP-3 LIST OF ILLUSTRATIONS/TABLES Page 2 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 10 - OPERATION MANUAL

OPERATION MANUAL NAV-402AP-3 1-1-1 Page 1 Sep 1/04 SECTION 1 - DESCRIPTION 1. GENERAL DESCRIPTION AND CAPABILITIES 1.1 DESCRIPTION The NAV-402

Page 11

OPERATION MANUAL NAV-402AP-3 1-1-1 Page 2 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK

Page 12

OPERATION MANUAL RAMP TEST SET NAV-402AP-3 PUBLISHED BY Aeroflex COPYRIGHT © Aeroflex 2004 All rights reserved. No part of this public

Page 13

OPERATION MANUAL NAV-402AP-3 1-2-1 Page 1 Sep 1/04 SECTION 2 - OPERATION 1. INSTALLATION 1.1 GENERAL The Test Set is powered by an internal batt

Page 14

OPERATION MANUAL NAV-402AP-3 1-2-1 Page 2 Sep 1/04 1.5 AC POWER REQUIREMENTS The Test Set operates over a voltage range of 100 to 120 VAC at 60

Page 15

OPERATION MANUAL NAV-402AP-3 1-2-1 Page 3 Sep 1/04 OUTNAV TONE0.5A @ 220VAC1.0A @ 110VACF2TYPE FF1PWR MONSIG GENDEMOD DEMOD115S23000920004AC IN

Page 16

OPERATION MANUAL NAV-402AP-3 1-2-1 Page 4 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 17

OPERATION MANUAL NAV-402AP-3 1-2-2 Page 1 Sep 1/04 2. CONTROLS, CONNECTORS AND INDICATORS 00906 00001 0.11.52 0244 0862 08 01030%100%-dBmOUTPU

Page 18 - SECTION 1 - DESCRIPTION

OPERATION MANUAL NAV-402AP-3 1-2-2 Page 2 Sep 1/04 CONTROLS, CONNECTORS AND INDICATORS IN NUMERIC ORDER CONTROLS, CONNECTORS AND INDICATORS IN

Page 19

OPERATION MANUAL NAV-402AP-3 1-2-2 Page 3 Sep 1/04 2.1 FRONT PANEL Refer to 1-2-2, Figure 2. ITEM DESCRIPTION 1. MONITOR Meter Provides, accordi

Page 20 - SECTION 2 - OPERATION

OPERATION MANUAL NAV-402AP-3 1-2-2 Page 4 Sep 1/04 ITEM DESCRIPTION 5. FREQUENCY MODE Switch Selects frequency band to be used: Marker (MKR),

Page 21

OPERATION MANUAL NAV-402AP-3 1-2-2 Page 5 Sep 1/04 ITEM DESCRIPTION 10. VAR FREQ Controls Coarse and fine controls manually channel sweep the i

Page 22 - AC IN CONNECTOR

OPERATION MANUAL NAV-402AP-3 1-2-2 Page 6 Sep 1/04 ITEM DESCRIPTION 17. AVG/PEAK LOC XMTR ON Switch Selects power meter function displayed on M

Page 24

OPERATION MANUAL NAV-402AP-3 1-2-2 Page 7 Sep 1/04 ITEM DESCRIPTION 23. LOC CENTER Adjust Varies the amplitude of the 90 Hz tone and controls e

Page 25

OPERATION MANUAL NAV-402AP-3 1-2-2 Page 8 Sep 1/04 ITEM DESCRIPTION 30. POWER ON Indicator Illuminates when applying ac or battery power to t

Page 26

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 1 Sep 1/04 3. GENERAL OPERATING PROCEDURES3.1 GENERAL This section contains operating instructions fo

Page 27

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 2 Sep 1/04 3.5 BENCH OPERATION Bench testing dictates the use of direct coaxial cable connections betwe

Page 28

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 3 Sep 1/04 3.9 MARKER OPERATION (TYPICAL CONTROL SETTINGS) STEP PROCEDURE 1. MONITOR METER FUNCTION

Page 29

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 4 Sep 1/04 3.10 VOR OPERATION (TYPICAL CONTROL SETTINGS) STEP PROCEDURE 1. MONITOR METER FUNCTION

Page 30

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 5 Sep 1/04 3.11 LOCALIZER OPERATION (TYPICAL CONTROL SETTINGS) STEP PROCEDURE 1. MONITOR METER FUN

Page 31

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 6 Sep 1/04 3.12 GLIDE SLOPE OPERATION (TYPICAL CONTROL SETTINGS) STEP PROCEDURE 1. MONITOR METER F

Page 32

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 7 Sep 1/04 3.13 COMMUNICATION OPERATION (RECEIVER TESTS) (TYPICAL CONTROL SETTINGS) STEP PROCEDURE 1

Page 33

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 8 Sep 1/04 STEP PROCEDURE 12. PWR/BAT Switch (cont) NOTE: Sequence repeats every 100 kHz, from

Page 34

OPERATION MANUAL NAV-402AP-3 Nomenclature Statement: In this manual Test Set or Unit refers to the NAV-402AP-3 Marker, G/S, VOR, COMM and Auto

Page 35

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 9 Sep 1/04 DECIBELS VOLTS WATTS DECIBELS VOLTS WATTS +40 dBw +39 dBw +38 dBw +37 dBw +36 dBw +35

Page 36

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 10 Sep 1/04 DECIBELS VOLTS WATTS DECIBELS VOLTS WATTS +0 dBm -1 dBm -2 dBm -3 dBm -4 dBm -5 dBm

Page 37

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 11 Sep 1/04 DECIBELS VOLTS WATTS -70 dBm -71 dBm -72 dBm -73 dBm -74 dBm -75 dBm -76 dBm -77 dBm -78

Page 38

OPERATION MANUAL NAV-402AP-3 1-2-3 Page 12 Sep 1/04 LOCALIZER TONE DIFFERENCE VALUES COURSE DEVIATION INDICATOR % MODULATION 90 Hz 1

Page 39

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 1 Sep 1/04 SECTION 3 - SPECIFICATIONS 1. NAV-402AP-3 SPECIFICATIONS NOTE: A 15 minute warm-up period i

Page 40

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 2 Sep 1/04 1.2 MARKER MODE Marker Tone Frequency Accuracy: 1020 Hz: ±1% 400 Hz: ±1% 1300 Hz:

Page 41

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 3 Sep 1/04 1.3 VOR MODE VOR Tone Frequency Accuracy: 30 Hz Reference: ±0.02% 30 Hz Variable: ±0

Page 42

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 4 Sep 1/04 1.4 LOC MODE LOC Tone Frequency Accuracy: 90 Hz: ± 0.02% 150 Hz Variable: ±0.02%

Page 43

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 5 Sep 1/04 1.5 G/S MODE LOC Tone Frequency Accuracy: 90 Hz: ± 0.02% 150 Hz Variable: ±0.02%

Page 44 - SECTION 3 - SPECIFICATIONS

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 6 Sep 1/04 1.6 COM MODE COM Tone Frequency Accuracy: 1020 Hz: ±1% 400 Hz: ±1% 1300 Hz: ±1%

Page 45

OPERATION MANUAL NAV-402AP-3 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 46

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 7 Sep 1/04 CAUTION: MAXIMUM INPUT POWER TO COUNTER IS LIMITED TO 250 mW OR +24 dBm. EXCEEDING THESE L

Page 47

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 8 Sep 1/04 1.9 BATTERY LEVEL MONITOR Range: 0 to 30 V Accuracy: ±5% of reading 1.10 BEARING MON

Page 48

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 9 Sep 1/04 SETTING ON VOR BEARING SELECT SWITCHES 150 Hz PHASE RELATIVE TO 90 Hz 000.0 0° 001.0 +

Page 49

OPERATION MANUAL NAV-402AP-3 1-3-1 Page 10 Sep 1/04 VOR BRG Switch Position 150 Hz Phase Relative to 90 Hz 000.0 001.0 002.0 003.0 004.0

Page 50

OPERATION MANUAL NAV-402AP-3 1-4-1 Page 1 Sep 1/04 SECTION 4 - SHIPPING 1. SHIPPING TEST SETS 1.1 INFORMATION Aeroflex Test Sets returned to f

Page 51

OPERATION MANUAL NAV-402AP-3 1-4-1 Page 2 Sep 1/04 TOP PACKINGMOLDTEST INSTRUMENTWRAPPED WITHPOLYETHYLENESHEETINGBOTTOM PACKINGMOLDSHIPPING C

Page 52

OPERATION MANUAL NAV-402AP-3 1-5-1 Page 1 Sep 1/04 SECTION 5 - STORAGE 1. STORING TEST SETS Perform the following storage precautions whenever

Page 53

OPERATION MANUAL NAV-402AP-3 1-5-1 Page 2 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 54 - SECTION 4 - SHIPPING

OPERATION MANUAL NAV-402AP-3 APPENDIX A Page 1 Sep 1/04 APPENDIX A - TABLE OF I/O CONNECTORS CONNECTOR TYPE SIGNAL TYPE INPUT/OUTPUT AC IN I

Page 55

OPERATION MANUAL NAV-402AP-3 APPENDIX A Page 2 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 56 - SECTION 5 - STORAGE

OPERATION MANUAL NAV-402AP-3 SAFETY FIRST: TO ALL OPERATIONS PERSONNEL REFER ALL SERVICING OF UNIT TO QUALIFIED TECHNICAL PERSONNEL. this unit

Page 57

OPERATION MANUAL NAV-402AP-3 APPENDIX B Page 1 Sep 1/04 APPENDIX B - METRIC/BRITISH IMPERIAL CONVERSION TABLE WITH NAUTICAL DISTAN

Page 58

OPERATION MANUAL NAV-402AP-3 APPENDIX B Page 2 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 59

OPERATION MANUAL NAV-402AP-3 APPENDIX C Page 1 Sep 1/04 APPENDIX C - ABBREVIATIONS A A Amperes AC, ac Alternating Current approx Approximate A

Page 60

OPERATION MANUAL NAV-402AP-3 APPENDIX C Page 2 Sep 1/04 W W Watts w/o Without X XMTR Transmitter XTL Crystal µA Microamperes µV Microvolts µW

Page 61

OPERATION MANUAL NAV-402AP-3 INDEX Page 1 Sep 1/04 INDEX 90 Hz and 150 Hz Tones Phase Relationships Table 1-3-1, p 10 Correspondence Chart

Page 62 - APPENDIX C - ABBREVIATIONS

OPERATION MANUAL NAV-402AP-3 INDEX Page 2 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 63

Our passion for performance is defined by threeattributes represented by these three icons:solution-minded, performance-driven, customer-focused.As we

Page 64

OPERATION MANUAL NAV-402AP-3 THIS PAGE INTENTIONALLY LEFT BLANK.

Page 65

OPERATION MANUAL NAV-402AP-3 LIST OF EFFECTIVE PAGES Page 1 Sep 1/04 LIST OF EFFECTIVE PAGES CHAPTER/SECTION/SUBJECT PAGE DATE Title / Copyright

Page 66

OPERATION MANUAL NAV-402AP-3 LIST OF EFFECTIVE PAGES Page 2 Sep 1/04 THIS PAGE INTENTIONALLY LEFT BLANK.

Comments to this Manuals

No comments